Geothermal AGS

From underground heat to power for digital infrastructure.

Advanced Geothermal Systems collect heat below ground. The RePG pathway combines a sealed subsurface circuit with a surface power module that converts part of that heat into electricity.

Explore how the system works, how it can support data centers and what distinguishes it from conventional geothermal generation.

Engineering and equipment assembly at our Main Global Engineering Center in Bursa. Photograph from the visit on 6 October 2026.
Explore the Bursa center

01 / HOW GEOTHERMAL AGS WORKS

Two separate circuits.
A continuous transfer of heat.

AGS describes the subsurface heat collection system. ORC, the Organic Rankine Cycle, describes the surface process that converts thermal energy into electrical energy. In the sealed RePG concept, a heat exchanger connects these two systems without mixing their fluids.

Conceptual illustration of the two circuits. Equipment arrangement and well geometry are illustrative and are not a construction drawing.
A / BELOW GROUND

The geothermal circuit

Heat moves from the rock into a fluid contained inside the well loop. This architecture is designed to avoid producing formation water to the surface.

B / AT THE SURFACE

The conversion circuit

An organic working fluid receives the heat, drives a generator through an expansion stage, condenses and circulates again.

C / ENERGY BALANCE

Useful power and remaining heat

Only part of the thermal input becomes electricity. Cooling rejects the remaining heat, while circulation pumps and other auxiliaries consume part of the generated power.

Closed-loop geothermal generationConceptual · not to scale

Swipe to explore the diagram

How a sealed geothermal loop supplies a separate ORC electricity cycleRock heats the fluid inside a closed underground loop. A surface heat exchanger keeps the geothermal and Organic Rankine Cycle fluids separate. The ORC evaporates, drives a turbine and generator, condenses using a cooling system, and is pumped back. Neither fluid mixes with the other.SUBSURFACE HEAT COLLECTIONINDEPENDENT ORC POWER CYCLEGROUNDHeat conducted through the pipe wallCoolerreturnHeatedfluidSealed loop01 · heat collectionEvaporator / HX02 · fluids isolatedORC vapourTurbine03 · expansionshaftGGeneratorPowerExhaustvapourCondenser04 · heat rejectionORC liquidPumpCoolingResidual heatClosed working-fluid cycle · separate from the geothermal loop
  1. Collect heat underground

    A heat-transfer fluid circulates inside sealed pipework. Heat passes from the surrounding rock through the pipe wall; the circuit does not rely on producing formation fluid.

  2. Transfer heat, keep fluids separate

    At the surface, the heat exchanger transfers thermal energy to a separate Organic Rankine Cycle working fluid, which evaporates at the designed operating conditions.

  3. Generate electricity

    The ORC vapour expands through a turbine coupled to a generator. Useful net output is the electrical generation remaining after pumps, cooling and other plant loads.

  4. Condense and circulate again

    A cooling system removes residual heat. The ORC fluid condenses and is pumped back to the evaporator, while the geothermal fluid returns underground in its own circuit.

Simplified functional arrangement, not a construction drawing. Well geometry, working fluids, heat exchangers, cooling and net electrical performance are designed for each site's measured conditions.
  1. 01

    Collect heat underground

    A fluid circulates inside a sealed well loop. Heat passes from the surrounding rock through the pipe wall into this fluid, which returns to the surface.

  2. 02

    Transfer heat at the surface

    An exchanger transfers the collected heat to a separate organic working fluid. The geothermal fluid and the ORC fluid stay in their own circuits.

  3. 03

    Generate electricity

    In the Organic Rankine Cycle, the heated working fluid vaporises and expands through an expander or turbine connected to an electrical generator.

  4. 04

    Condense and circulate again

    A condenser releases the remaining heat to a cooling system. A pump returns the organic fluid to the exchanger, while the geothermal fluid returns underground.

02 / GEOTHERMAL AGS FOR DATA CENTERS

Powering computation.
Managing heat as a resource.

Data centers need continuous electricity for servers, networking, storage and cooling. An AGS installation can be designed to contribute to that electrical demand by using underground heat as its energy source. A second, separate opportunity is to recover suitable heat already leaving the servers.

PATH A / GEOTHERMAL GENERATION

Bring energy into the campus

The subsurface circuit supplies heat to an ORC module. Its net electrical output feeds the campus distribution system alongside the other power supplies. The proportion of campus demand it can cover depends on the geothermal resource, system size and measured operating performance.

PATH B / SERVER HEAT RECOVERY

Recover part of the outgoing heat

A suitable warm liquid cooling circuit can transfer heat through an isolated exchanger to a dedicated recovery module. This option needs sufficient temperature and flow, plus a colder heat sink. It recovers a fraction of waste energy and is assessed separately from underground generation.

Geothermal AGS for data centresConceptual · not to scale

Swipe to explore the diagram

Separate geothermal power supply and optional data centre heat recoveryAn independent geothermal power plant and the grid feed a data centre electrical bus through the appropriate controls. The UPS and backup system remain. Optional liquid cooling heat passes through an isolation exchanger to a separately assessed recovery module, which may contribute electricity. Residual heat goes to cooling or useful heat demand. No energy loop is self-sustaining.PRIMARY ELECTRICAL SUPPLYGeothermal AGS plant01 · independent heat resourceNet electrical outputSite electrical busProtection and controlsGrid / backup / UPS04 · resilience retainedElectrical supplyData centreIT load and engineered coolingOPTIONAL HEAT RECOVERYRecovery module03 · assess net useful outputConditional contributionIsolation HX02 · separate fluidsHeat rejection04 · cooling / useful heatResidual heat from recovery must also be managedResource + thermal design + electrical resilience + verified net energy balance
  1. Supply from a geothermal resource

    An independently assessed geothermal plant can contribute electricity to the site's electrical distribution. Its output depends on the resource and the complete plant energy balance.

  2. Capture suitable server heat

    Where liquid cooling provides suitable temperature and flow, an isolation heat exchanger can transfer server heat to a separate recovery circuit without mixing the cooling fluids.

  3. Evaluate additional recovery

    An optional recovery module can contribute electricity only where a validated temperature difference and net energy balance support it. Direct heat use is an alternative where a compatible demand exists.

  4. Retain resilient power and cooling

    Grid supply, UPS, backup power and designed cooling capacity remain part of the data centre infrastructure. Unrecovered heat still has to be rejected or used by a separate heat demand.

Illustrative integration architecture, not a promise of autonomous operation. Server heat is a by-product of energy already consumed. Recovering part of it cannot create a self-powering data centre.

Cooling remains an essential system

Warm server coolant, sometimes designed around 55–70°C in the company’s scenarios, is different from ordinary low temperature chilled water. A heat recovery module must match the actual cooling technology and must not compromise server inlet conditions.

Residual heat still needs to be rejected. Bypasses and an independent cooling path allow the data center to operate when a recovery unit is unavailable. Direct use of the heat in a nearby building or process should also be compared with electrical conversion.

From concept to a working data center installation

  1. 01

    Define the electrical load

    Measure the IT load, cooling demand, auxiliary services and hourly operating profile. Size the geothermal contribution against the campus’s real demand and resilience requirements.

  2. 02

    Qualify the heat sources

    Characterise underground temperature and sustainable heat extraction. Separately measure the temperature, flow and availability of any server cooling loop proposed for heat recovery.

  3. 03

    Engineer the interfaces

    Use isolated heat exchangers, dedicated controls and bypasses. Integrate the generator with the campus electrical system, protection equipment and energy management controls.

  4. 04

    Validate the complete balance

    Test net electrical output, pumping power, cooling duties and seasonal performance. Retain heat rejection capacity, grid connections, UPS and backup arrangements required by the facility.

The same surface conversion principle can also recover suitable industrial process heat or use an existing geothermal stream. These applications have different heat sources and do not, by themselves, demonstrate an integrated sealed AGS field.

Read the Geothermal AGS for Data Centres report

03 / AGS AND TRADITIONAL GEOTHERMAL

The difference starts
below ground.

Conventional hydrothermal generation brings naturally occurring hot fluid to the surface. The sealed AGS concept circulates its own fluid inside underground pipes and collects heat through their walls. The distinction is how heat is obtained, rather than the use of ORC alone.

Two different ways to access underground heatConceptual · not to scale

Swipe to explore the diagram

Conventional hydrothermal extraction compared with sealed closed-loop heat collectionThe left diagram shows reinjected and produced geothermal fluid moving through a permeable rock reservoir. The right diagram shows fluid confined to an engineered sealed pipe loop, heated through the pipe wall. Both transfer heat to surface equipment and both require a site-specific assessment.Conventional hydrothermalSealed closed-loopGROUNDGROUNDSurface heat usePower and / or useful heatSurface heat usePower and / or useful heatFluid moves through reservoir rockReinjectionProductionHeat conducted into the loopWorking fluid stays inside sealed pipesCooler flowHeated flowDifferent heat-access mechanisms · site-specific design and assessment in both cases
  1. Conventional hydrothermal

    Geothermal fluid is produced from a naturally permeable reservoir. Heat is used at the surface and fluid is typically reinjected. Reservoir flow, fluid chemistry and resource management are central design considerations.

  2. Sealed closed-loop concept

    A separate heat-transfer fluid remains inside engineered pipes. Heat crosses the rock and pipe wall by conduction. Heat-transfer area, thermal conductivity, circulation losses and the long-term temperature response remain decisive.

This compares conventional hydrothermal extraction with a sealed closed-loop concept. It does not represent every geothermal technology: enhanced geothermal systems are a separate category. Both approaches require geological, technical, environmental and economic assessment; neither has a universal depth or zero-risk guarantee.
Conventional hydrothermal and the sealed RePG AGS concept
Design questionConventional geothermalSealed AGS concept
Heat collectionHot water or steam is produced from a natural geothermal reservoir, usually with reinjection after use.A circulating fluid collects heat through the walls of sealed underground pipes.
Reservoir requirementsPower production depends on suitable heat, fluid availability and reservoir permeability.The sealed concept does not require production flow through a naturally permeable reservoir. Rock temperature and heat transfer remain decisive.
Fluid and rock contactProduced geothermal fluid has been in contact with the formation; its chemistry must be managed.The circulating fluid stays inside the sealed well circuit. Well integrity and material durability must be verified.
Power conversionSteam or binary power cycles can be used, depending on resource conditions. Binary plants can also use ORC.The RePG pathway couples sealed heat collection with a separate surface ORC power block.
Depth and outputResource temperature, geology and reservoir performance determine well design and output.Depth, well geometry, temperature, thermal drawdown and pumping losses determine the practical design. There is no universal depth or output.
Development and validationConventional hydrothermal power has an established operating history, with performance specific to each field.RePG reports operating evidence for the surface conversion platform; its integrated subsurface AGS pathway has a separate pilot and qualification programme.

04 / ENGINEERING & FIELD EVIDENCE

The operating evidence.
The next validation steps.

The documented Hayat Kimya and AFJET installations provide evidence for the surface conversion platform under two different thermal regimes. The integrated subsurface AGS system has a separate development pathway.

COMPANY REPORTED MATURITYTRL 9

Surface ORC power block

Factory built equipment with documented operating records at the Hayat Kimya and AFJET installations, including monitoring and control systems.

COMPANY REPORTED MATURITYTRL 7

Integrated subsurface AGS

A separate qualification and pilot pathway addressing subsurface integration, real environment performance and subsequent scale up.

INDUSTRIAL HEAT RECOVERY

Hayat Kimya

Installed capacity
75 kWe
Mean net output
48.4 kW
Availability
97.5%
Operating period
4,248 h
Net generation
205.5 MWh

Figures from the nine page field report for July 2024 to January 2025. Later host interface maintenance and the reported return to service are recorded separately.

EXISTING GEOTHERMAL CIRCUIT

AFJET

Installed capacity
15 kWe
Measured net output
12.7 kW
Inlet / return temperature
72 / 66°C
Source flow
25 m³/h
Thermal input
175 kWt

The documented unit uses an existing permitted geothermal reinjection circuit. No new well was drilled for this installation.

Open the complete field evidence report
Equipment assembly and engineering work in Bursa.
Power equipment, pipework and control systems. Original visit photographs, 6 October 2026.
View further manufacturing photographs

05 / EUROPEAN AGS PILOT PROJECT

Augusto Innovation Hub.
Milazzo, Sicily.

R. Rockefeller S.C. is developing its first European AGS geothermal pilot project for Augusto Innovation Hub, with RePG as its industrial and technological partner.

The pilot is intended to test how geothermal energy can support the planned campus’s data center infrastructure and continuous energy needs. It connects the geothermal programme with the Hub’s activities in Super Intelligence, cybersecurity and digital infrastructure.

Project status: in development

Explore Augusto Innovation Hub
Augusto Innovation Hub campus at night, architectural design by Giancarlo Zema Design Group
Augusto Innovation Hub, the proposed European pilot context.

06 / CERTIFICATIONS & COMPLIANCE

Documentation with
a defined scope.

The certification file separates management systems, engineering test reports and the RE-75 kW product attestation. Each document applies to its stated scope and is distinct from qualification of a complete integrated AGS installation.

MANAGEMENT SYSTEMS

Quality, environment and safety

  • ISO 9001:2015
  • ISO 14001:2015
  • ISO 45001:2018
MACHINERY & ELECTRICAL

Engineering test framework

  • TS EN ISO 12100
  • TS EN 60204-1:2018
  • EN IEC 61000-6-2 / -4
PRODUCT ATTESTATION

RE-75 kW compliance file

  • 2006/42/EC
  • 2014/35/EU
  • 2014/30/EU
Open certification file

07 / DOCUMENT LIBRARY

Read the technical
and research documents.

Five documents cover the engineering center, AGS technology, data center applications, certification scopes and operating evidence. The current 56 page Centre & Research Lab presentation is included below.

RRSC / RePG Global Engineering & Research Centre cover
CENTRE & RESEARCH LAB

RRSC / RePG Global Engineering & Research Centre

Explore our main global engineering centre in Bursa, its research laboratory, geothermal AGS technologies, data centre energy systems, industrial heat recovery and international pilot projects.

56 PAGES · ENGLISH · 37.7 MB
RePG Technical & Strategic Report 2026 cover
TECHNOLOGY & STRATEGY

RePG Technical & Strategic Report 2026

ORC platform, AGS pathway, applications, evidence and strategic framework.

48 PAGES · ENGLISH
Geothermal AGS for Data Centres cover
DATA CENTERS & INDUSTRY

Geothermal AGS for Data Centres

Modular concepts, thermal integration and proposed energy configurations for data centers.

21 PAGES · ENGLISH
RePG Geothermal Certifications 2026 cover
CERTIFICATION FILE

RePG Geothermal Certifications 2026

Facsimiles covering distinct management, test report and product scopes.

5 PAGES · ENGLISH
Hayat Kimya & AFJET Pilot Report cover
MEASURED FIELD EVIDENCE

Hayat Kimya & AFJET Pilot Report

Configuration, operating conditions and measured surface power block performance.

9 PAGES · ENGLISH

REPG GEOTHERMAL AGS

Explore the engineering
behind the platform.

Bursa engineering center Company PDF Files Return to top
Home